The electrostatic condensate separator JUNIPER reliably and cost-effectively removes condensable organic compounds like those that accrue in manufacturing fabs in the photovoltaic industry. Many of these organic compounds have a bad odour and many of them are toxic. JUNIPER is capable of handling waste gas flows up to
600 m3/h. Separation rates are above 90 %.
The system prevents exhaust blockage through condensates by reducing the overall carbon content of waste gases, and in addition, separates dusts from the waste gases.
Operating Principle
With JUNIPER waste gas flows are entered quickly into the system. Hot waste gas enters a cooler and the tempature is reduced to the organic compounds’ condensation temperature. Afterwards, aerosols are channeled through separator columns, where it ionized, and condensed components are deposited on grounded metal tubes. Then separated condensate flows back into the tank where it is collected. It can be pumped out automatically or drained manually.
Your Advantages
- Efficient reduction of condensable organic carbon compounds
- Collection of the condensate in a tank
- Collection of dust particles
- High safety standards (all critical parameters are sensor monitored)
- Interface to upstream process systems
Technical Data
- Dimensions (B x T x H):
1500 mm × 1000 mm × 2100 mm
Access to maintenance area on front and back side - Gas entry: 1 x DN150
- Gas flow: max. 600 m³/h
- Precipitation rate: > 90 %